131584 | Manufacturer: Osram | EAN: 4008321131584 | MPN: QTP8-1-18

QTP8 1x18W 230 240V quicktronic professional electronic ballasts grade


17,08 € tax excl.

Price for 1 piece, excluding shipping costs!

Competitive price
Verified quality
Fast shipping
Secure payment
Purchase per company
Advice by staff
QUICKTRONIC PROFESSIONAL 8 ECG for FL 26 mm. Automatic restart after lamp replacement. Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100. Supply voltage: 220 - 240V, Line voltage:198 -264V, Line frequency:50Hz...60Hz. Lamp start with optimum filament preheating. Lifetime:>100000h (for T=65°C at Tc). Safety: to EN61347-2-3, Lamp operation: to EN60929, RI suppression: to EN55015:2006 A1:2007 A2:2009/CISPR15, Line harmonics according to EN61000-3-2, Immunity according to EN61547.
    More info

    More info

    Osram QTP8 1x18W 230 240V quicktronic professional electronic ballasts grade Ballast. Enhance your lighting with the QTP8 1x18W Quicktronic professional electronic ballast. Achieve optimal brightness effortlessly at 230-240V.

    Input voltage AC 198 - 264 V
    Nominal voltage 220 - 240 V
    Mains frequency 50 - 60 Hz
    Input voltage DC 154…276 V
    Operating frequency 45…60 kHz
    Max. ECG no. on circuit breaker 10 A (B) 36
    Max. ECG no. on circuit breaker 16 A (B) 59
    Inrush current 14 A
    Starting time 2s
    Length 360 mm
    Width 30 mm
    Height 30 mm
    Mounting hole spacing, length 350 mm
    Ambient temperature range –25…+55 °C
    Permitted rel. humidity during operation 5…85%
    ECG lifetime 100000 h
    Suitable for fixtures with prot. class I / II
    End of lamp life safety shutdown EOL T.2
    Approval marks - approval VDE / VDE-EMC / ENEC 10
    EEI - Energy Label A2
    Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015: 2006 + A1: 2007/Acc. to EN 61000 - 3-2/Acc. to EN 61547
    Protection class III
    Type of protection IP20

    Benefits
    • Automatic restart after lamp replacement

    Applications
    • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100

    Features
    • Supply voltage: 220 - 240 V
    • Line voltage: 198 - 264 V
    • Line frequency: 0 Hz, 50 Hz…60 Hz
    • Lamp start with optimum filament preheating
    • Life time: > 100000 h (for T = 65 °C at Tc)
    • Safety: to EN 61347-2-3
    • Lamp operation: to EN 60929
    • RI suppression: to EN 55015: 2006+A1: 2007+A2: 2009/CISPR 15
    • Line harmonics according to EN 61000 - 3-2
    • Immunity according to EN 61547

    Explanation Dimmable no
    Explanation Voltage - (V) 220
    Explanation Protection mark - (IPXX) 20
    Explanation Lifetime - (h) 100000
    Explanation Factory packed - (pieces) 20

    Download Lamp ECG combination

    General safety informations

    Reviews

    Reviews

    There are currently no comments for this product.

    Write your own review

    Add to compare

      There are no products selected for comparison.