Philips HF-B 236 TL-D EII 220-240V

931580 - Philips - 8711500931580 - 913700192866

HF-Basic TL-D EII je zanesljiva in visokofrekvenčna elektronska predstikalna naprava za TL-D fluorescentne sijalke. Idealna alternativa za elektromagnetne predstikalne naprave (EM).

Več podatkov

16,53€brez DDV


Teža: 0.22 kg
Dostava: 1 do 3 dni
Stanje: Nov izdelek

- +

0
  0 / 5 - 0 komentarjev  Dodaj komentar



 
Podrobnosti

Application code EII
Rated Lamptype TL-D
Rated Number of Lamps 2 piece
Rated Ballast-Lamp Power 36W
Line Voltage 220-240V
Line Frequency 50/60 Hz
Energy Efficiency Index A2
Lifetime 90% surv.@Tcaselife 50000 hr
Ignition Method Cold Start

Automatic restart Yes
Ignition time 0.5 (max) s
Operating frequency 42 (min), 45 (nom) kHz
Mains voltage safety (AC) -10%/+10%
Mains voltage performance (AC) -8%/+6%
Inrush current Peak 18 (max) A
Inrush current Width 0.25 ms
Earth leakage current 0.5 mA
Power losses gear 4.0W
Constant wattage deviation -2%/+2%
Ballast Lumen Factor 0.95 -
PowerFactor 100% output power 0.96 -
Battery voltage lamp ignition 198-254V
Battery voltage running lamps 176-254V
Overvoltage protection 320Vac 48 hr
Overvoltage protection 350Vac 2 hr
Max ballast on MCB(16A type B) 28 x
Crestfactor 1.7 (max) -
Hum and Noise level Inaudible
Total Harmonic Distortion EUR 15 %

Cable-Cap outputwires to earth 120 pF
Cable-Cap outputwires mutual 120 pF
Conn.type input terminals WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Conn.type output terminals WAGO 251 universal connector [Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Max. cable length Device/Lamp 2.00 m
Max. cable length Hot Wires 0.75 m
Striplength 8.0-9.0 mm
Dual fixture Master/Slave Yes [Master/Slave operation possible]
Wcs Input terminals 0.50-1.00 mm2
Wcs Output terminals 0.50-1.00 mm2
Wcs auto insertion (ALF/ADS) 0.5 mm2

Rated Lamp Power on TL-D 36W
System Power on TL-D 36.5W
Lamp Power on TL-D 32W
Power Loss on TL-D 4.5

T-case life 75 C
T-case maximum 75 (max) C
T-ignition -15 (min), 50 (max) C
T-ambient -15 (min), 50 (max) C
T-storage -40 (min), 80 (max) C

Length A1 280.0 mm
Fixing Hole Distance Length A2 265.0 mm
Width B1 30.0 mm
Height C1 28.0 mm
Fixing Hole Diameter D1 4.2 mm

Approval marks ENEC / VDE-EMV
CE marking Yes
Temperature marking 110 [Yes]
Emergency standard IEC 60598-2-22


-Savings of 25% energy compared to electromagnetic “C-type” ballasts
-Instant start gives “direct” light
-HF-operation eliminates eye strain as caused by electromagnetic ballasts
-No igniter/capacitor needed, simplified wiring compared to Electromagnetic
-The HF-B TLD range has a robust design and meets internal safety, EMC and Immunity tests
-Offers the flexibility for simple wiring release possibility
-Including safety approbation via an external test-house covering IEC/EN 61347
-Automatic restart (after voltage dip or lamp exchange) ensures easy operation

Applications
-Designed for applications where lamps burn for a long period of time and switching cycle (on/off) is infrequent (e.g. maximum 3 times a day)
-Ideal for installations such as department stores, airports, offices
-Suitable for high risk or explosive areas

Philips HF-B 236 TL-D EII 220-240V 8711500931580 913700192866

 
Tehnični podatki
Možnost zatemnitveNe
Napetost - volt (V)220-240
Življenska doba - ure (h)50000
Tovarniško pakiranje - kosov (kos)12